Influence of Pharyngeal Anaesthesia on Post-Bronchoscopic Coughing: A Prospective, Single Blinded, Multicentre Trial

Häntschel, M., Zahn-Paulsen, M., Ehab, A., Böckeler, M., Spengler, W., Lewis, Richard, Hautmann, H. and Hetzel, J. (2021) Influence of Pharyngeal Anaesthesia on Post-Bronchoscopic Coughing: A Prospective, Single Blinded, Multicentre Trial. Journal of Clinical Medicine, 10 (20). p. 4773. ISSN EISSN 2077-0383

[thumbnail of jcm-10-04773-v2.pdf]
Preview
Text
jcm-10-04773-v2.pdf - Published Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

Background: Local anaesthesia of the pharynx (LAP) was introduced in the era of rigid bronchoscopy (which was initially a conscious procedure under local anaesthetic), and continued into the era of flexible bronchoscopy (FB) in order to facilitate introduction of the FB. LAP reduces cough and gagging reflex, but its post-procedural effect is unclear. This prospective multicentre trial evaluated the effect of LAP on coughing intensity/time and patient comfort after FB, and the feasibility of FB under propofol sedation alone, without LAP. Material and methods: FB was performed in 74 consecutive patients under sedation with propofol, either alone (35 patients, 47.3%) or with additional LAP (39 patients, 52.7%). A primary endpoint of post-procedural coughing duration in the first 10 min after awakening was evaluated. A secondary endpoint was the cough frequency, quality and development of coughing in the same period during the 10 min post-procedure. Finally, the ease of undertaking the FB and the patient’s tolerance and safety were evaluated from the point of view of the investigator, the assistant technician and the patient. Results: We observed a trend to a shorter cumulative coughing time of 48.6 s in the group without LAP compared to 82.8 s in the group receiving LAP within the first 10 min after the procedure, although this difference was not significant (p = 0.24). There was no significant difference in the cough frequency, quality, peri-procedural complication rate, nor patient tolerance or safety. FB, including any additional procedure, could be performed equally well with or without LAP in both groups. Conclusions: Our study suggests that undertaking FB under deep sedation without LAP does to affect post-procedural cough duration and frequency. However, further prospective randomised controlled trials are needed to further support this finding.

Item Type: Article
Additional Information:

This article belongs to the Special Issue Interventional Pulmonology: A New World.

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

Uncontrolled Discrete Keywords: bronchoscopy, pharyngeal anaesthesia, cough
Divisions: College of Health, Life and Environmental Sciences > School of Science and the Environment
Related URLs:
Copyright Info: Open Access article
Depositing User: Janet Davidson
Date Deposited: 19 Nov 2021 14:12