University of Worcester Worcester Research and Publications
 
  USER PANEL:
  ABOUT THE COLLECTION:
  CONTACT DETAILS:

Car Cabin Filters as Sampling Devices to Study Bioaerosols Using eDNA and Microbiological Methods

Hurley, Kirsty, Wharton, Laura, Wheeler, Mike, Skjøth, C. ORCID: https://orcid.org/0000-0001-5992-9568, Niles, Christian and Hanson, Mary (2019) Car Cabin Filters as Sampling Devices to Study Bioaerosols Using eDNA and Microbiological Methods. Aerobiologia, 35 (2). pp. 215-225. ISSN 0393-5965

[thumbnail of Test System for CAF Final Draft.pdf]
Preview
Text
Test System for CAF Final Draft.pdf - Accepted Version

Download (178kB) | Preview
[thumbnail of Fig1.pdf]
Preview
Image
Fig1.pdf

Download (87kB) | Preview
[thumbnail of Fig2.pdf]
Preview
Image
Fig2.pdf

Download (36kB) | Preview
[thumbnail of Fig3.pdf]
Preview
Image
Fig3.pdf

Download (39kB) | Preview

Abstract

The aim of this study was to examine whether bioaerosols could be isolated and quantified from used car cabin filters. Car cabin filters are widely available and can provide a vast untapped resource for sampling of bioaerosols in areas with enhanced air pollution. We developed a test system where we exposed car cabin filters to birch pollen under compressed air to represent airflow onto the filter. The flow of pollen within the test system was confirmed by microscopy and real-time PCR. Testing of extraction methods was performed on the most prevalent types of filters in UK cars and confirmed it was possible to extract and quantify viable fungi, birch pollen or proteins from car filters. The main challenge of their use is envisaged to be the lack of temporal resolution as car cabin filters are not routinely changed at intervals greater than 1 year; however, the systematic recording of the different routes driven during the sampling interval has been enabled through the common use of GPS, smartphones or similar technologies. Car filters therefore provide substantial possibilities to monitor exposure of harmful bioaerosols in the polluted traffic regions defined by the road network. This method could also be applied to studying allergen exposure associated with bioaerosols and their delivery into the human respiratory system. These findings demonstrate that car cabin filters have the potential to be used to isolate and quantify a range of bioaerosols including pollen and fungi, as well as fractions of bioaerosols, such as proteins.

Item Type: Article
Additional Information:

Staff and students at the University of Worcester have access to the full-text of the online published version via the UW online Library Search. External users should check availability with their local library or Interlibrary Requests Service.

Uncontrolled Discrete Keywords: bioaerosols, pollen, fungi, filters, environment, allergy
Subjects: Q Science > Q Science (General)
Q Science > QR Microbiology
Divisions: College of Health, Life and Environmental Sciences > School of Science and the Environment
Related URLs:
Depositing User: Mary Hanson
Date Deposited: 26 Jan 2019 09:11
Last Modified: 10 Sep 2020 11:24
URI: https://worc-9.eprints-hosting.org/id/eprint/7506

Actions (login required)

View Item View Item
 
     
Worcester Research and Publications is powered by EPrints 3 which is developed by the School of Electronics and Computer Science at the University of Southampton. More information and software credits.